Cobetter gamma irradiatable capsule filters incorporated with hydrophobic PVDF membrane,features high flow rate and 100% bacterial retention ,which are specially suitable for sterile filtration of air and gas in biopharmaceutical,even in some presence of high moisture.
Filter Media Pore Size | Hydrophobic PVDF 0.2μm |
Filter Structure Components | Gamma Stable Polypropylene |
Bacterial Retention | Retention of 107 CFU/cm2 Brevundimonas diminuta (ATCC?19146) according to ASTM F838. |
Max. Temperature | 41℃ |
Max. Differential Pressure | 3.5 bar/ 41℃ |
Sterilization Method | - Gamma Irradiation: 25 kGy recommend 50kGy maximum - Autoclaved for1 cycles of 30 minutes at 135℃. (No in-line steam sterilization) |
Bacterial Endotoxin | <0.25EU/mL, according to LAL Test |
Component Material Toxicity | Meets USP Biological reactivity test for Class VI-121℃ Plastics |