Process water in many industries requires dissolved gases removal or injection, Arrayforce? Gas-Liquid membrane contactor provides a highly efficient, energy-saving and environmental friendly gas-liquid separation/mix solution for various industries by utilizing hollow fiber membrane with excellent hydrophobic property.
Basic introduction of
Arrayforce? gas-liquid separation membrane contactor
Process water in many industries requires dissolved gases removal or gases injection.
Arrayforce? gas-liquid membrane contactor provides a highly efficient, energy-saving and environmental friendly gas-liquid
separation/mix solution for various industries by utilizing hollow fiber membrane with excellent hydrophobic property.
How membrane contactor works:
In typical operation, liquid to be degassed flows outside the hollow
fiber. At the same time, vacuum, sweep gas or a certain adsorption
liquid go through inside the hollow fiber.
There are a lot of micro pores on the surface of hydrophobic hollow
fiber, which allow gas molecules pass through, but reject water molecules.
Under the force caused by vacuum, sweep gas or adsorption
liquid, the gases dissolved in liquid outside the hollow fiber moves
continuously through the micropores to the inside hollow fiber, and
then is taken away by vacuum, sweep gas or a certain adsorption liquid.
In this way, dissolved gases in liquid is removed.
Ergonornically designed handle facilities fast and easy Installation and remove without special tools.
Model | Membrane Area | Flux | Hollow Fiber Material | Housing Material | Working Temperature | Max Pressure Shell/Lumen | PH Tolerance | |
1×5.5 2×6 2.5×8 4×13 6×28 8×20 10×28 | 0.1 m2 0.35 m2 1.41 m2 7.66 m2 42 m2 53 m2 130 m2 | 30 ~ 300 ml/min 50 ~ 1000 ml/min 1.67 ~ 11.67 L/min 3.33 ~ 50 L/min 1 ~ 10 m3/h 1 ~ 10 m3/h 6 ~ 40 m3/h | PMP/SP PMP/SP PP/PMP/SP PP/PMP/SP PP PP PP | PMP/SP PMP/SP PP/PMP/SP PP/PMP/SP PP PP PP | 5~70°C ———————— 5~45°C | 7 / 2 bar | 1~14 |
Hollow Fiber Material | Liquid Material Surface Tension | Liquid Material Viscosity |
PP PMP SP | ≥60 Dyne/cm ≥32 Dyne/cm ≥27 Dyne/cm | ≤ 50cp ≤ 50cp ≤ 10cp |
Compared with conventional degassers, Arrayforce? membrane contactors
have the following advantages:
· Expandable: no matter treatment capacity increase or gas removal efficiency improvement, you can make it
through adding membrane contactors in parallel of series;
· No chemical dosing: no chemical elements increase in water, saving cost of subsequent treatment;
· Quick start: simple operation process, time required for system stability is very short.
For technical data sheet or application inquiry, you are more than welcome to contact our sales representative by info.industry@cobetterfilter.com or leave a message.